Elevated serum OX40L is a biomarker for identifying corticosteroid resistance in pediatric asthmatic patients

Research article - Open Access - Open Peer Review

Su-Li Ma and, Lei Zhang Email author

Open Peer Review reports

Abstract

Background

Corticosteroids are widely used to control asthma symptoms, but steroid resistance (SR) is a common adverse reaction. Therefore, it is important to accurately predict the corticosteroid response of asthmatic patients. This study aims to evaluate the serum OX40 ligand (OX40L) in pediatric asthmatic patients, and to investigated its correlations with clinical characteristics and corticosteroid response.

Methods

A total of 192 pediatric asthmatic patients with inhaled corticosteroid (ICS) therapy and 130 healthy controls were selected. Clinical data were collected, and the serum levels of immunoglobulin (IgE), interleukin-6 (IL-6), thymic stromal lymphopoietin (TSLP), and OX40L were measured by enzyme-linked immunosorbent assay (ELISA). The level of serum OX40L was compared between the steroid-sensitive asthma (SSA) and steroid-resistant asthma (SRA) groups.

Results

The serum OX40L level in asthmatic patients (713.5 ± 165.7 pg/mL) was significantly higher than that of the healthy controls (238.6 ± 27.8 pg/mL) (P < 0.001), and significantly higher in SRA group (791.2 ± 167.9 pg/mL) than in SSA group (655.6 ± 138.8 pg/mL) (P < 0.001). The serum OX40L level showed a significant positive correlation with serum IgE, blood percentages of eosinophils and neutrophils, serum IL-6 and TSLP, and showed a negative correlation with asthma control test (ACT) score and forced expiratory volume in first second (FEV1%). Receiver operating characteristics (ROC) curve was performed to obtain a cutoff value of serum OX40L as 780 pg/mL (sensitivity = 58.5%; specificity = 86.4%), which can identify SRA in asthmatic patients. Multivariate logistic regression analysis showed that elevated serum OX40L (≥780 pg/mL), as well as lymphocytes (%), ACT score, serum IL-6 and TSLP, were independent predictors of SRA (OX40L ≥ 780 pg/mL: odds ratio = 4.188; 95% CI = 1.800–9.746; P = 0.001). The serum OX40L level was decreased after ICS treatment in asthmatic patients, and the reduction in serum OX40L was significant higher in SSA group compared with SRA group.

Conclusion

High serum OX40L can be used as a biomarker to identify asthmatic patients with corticosteroid resistance, and the change in OX40L level also reflects the response to ICS treatment. These results suggest an association of OX40L with the pathophysiology, inflammation, and clinical outcomes of asthma. New agents targeting OX40L can provide more precise and personalized therapy for asthma.

Download PDF

 

(You must be logged in to add and reply comments)

Interasma on Twitter

Interasma Top story: World Health Organization releases guidelines for digital health adoption | MobiHealthNews… https://t.co/6DcfNz3h2R
5hreplyretweetfavorite
Interasma RT @worldallergy: WAO and the French Allergy Society (SFA) invite you to submit an abstract for the World Allergy Congress 2019 that will b…
14hreplyretweetfavorite
Interasma RT @Aller_MD: “Association of Rhinovirus C Bronchiolitis and Immunoglobulin E Sensitization During Infancy With Development of Recurrent Wh…
14hreplyretweetfavorite
Interasma RT @Aller_MD: “Lentiviral vector gene therapy with low-exposure, targeted busulfan in infants with newly diagnosed SCID-X1 resulted in mult…
14hreplyretweetfavorite

Editor: Juan C. Ivancevich, MD

Copyright © Interasma 2003-2017  •  Terms of Use  •  Privacy Policy  •  Contact Us  •  Sitemap

Powered by FREI SA

InterAsma